  1. Type of paper: Paper in journal

    Title: Testing of Low Stray Inductivity Transformers by Atmospheric Voltage Impulse

    Authors:
    Kelemen, Tomislav (20682)
    Brkić, Luka (139293)
    Gardijan, Rajko (134475)
    Journal: ENERGIJA
    Number: 6
    ISSN: 0013-7448
    Volume: 41
    Year: 1992
    Pages: from 369 to 373
    Number of references: 6
    Language: hrvatski
    Summary: When testing the transformers of low stray inductivity byatmospheric voltage impulse, it is necessary to modify thecomercial impulse generator by building in some new components.In the work, the parameters of new components are determined anda typical transformer with low stray inductivity is tested bymodified impulse generator.
    Keywords: transformer, atmospheric voltage impulse, impulse generator

  2. Type of paper: Paper in journal

    Title: Power Transformer Maintenance

    Authors:
    Mikulecky, Antun (134543)
    Čabrajac, Sonja (7516)
    Journal: ENERGIJA
    Number: 6
    ISSN: 0013-7448
    Volume: 40
    Year: 1991
    Pages: from 389 to 397
    Number of references: 6
    Language: hrvatski
    Summary: Suitable power transformer maintenance is one of thepreconditions of its reliable service. It includes both thecontrol ( state diagnosis ) and the transformer maintenance. Inthis work, diagnosis methods and procedures are described, thatcan be applied when transformers are operating and the frequencyof those methods is recommended. The basic maintenance proceduresof significant power transformer components are also described.This work is the result of long-time transformer behaviourobservation, the study of transformer faults, literature andregulation, and it should be considered a reminder onoil-immersed power transformer maintenance.
    Keywords: maintenance of power transformer, diagnostic tests, insulating system, servicing

  3. Type of paper: Paper in journal

    Title: Steady State Calculation of Transmission Network by Renormalisation ofState Variables

    Authors:
    Bodlović, Petar (4186)
    Nemec, Darko (132335)
    Journal: ENERGIJA
    Number: 1
    ISSN: 0013-7448
    Volume: 41
    Year: 1992
    Pages: from 27 to 35
    Number of references: 3
    Language: hrvatski
    Summary: The paper presents a method of steady-state calculation inelectrical networks using coordinated complex renormalisation ofstate variables and network parameters. A physical interpretationis given and numerical aspects of introduced transformation areanalysed and validated by test results.
    Keywords: Power flows, State estimation, EPS analysis

  4. Type of paper: Paper in journal

    Title: The Maxwell's Potential Coefficient Matrix for the Electric Field Equivalent Homogenous Ladder Network

    Authors:
    Bodlović, Petar (4186)
    Kelemen, Tomislav (20682)
    Gojčeta, Zoran (129075)
    Journal: ELEKTROTEHNIKA
    Number: 1-2
    ISSN: 0013-5844
    Volume: 37
    Year: 1994
    Pages: from 17 to 22
    Number of references: 4
    Language: hrvatski
    Summary: After explanation of the role of electrostatic field theory in microstructural modelling of surge propagation in the single layer transformer coil, the capacitive ladder network is discussed as the equivalent circuit for the electrical field in the axial plane of the winding. Partial capacitances are available from the coil geometry, the capacitance matrix is tridiagonal, and the main effort is to compute algebraically its inverse - the Maxwell's potential coefficients matrix P. It appears that P is generally close to the Toeplitz matrix realized in a special case which will be taken as the basic one. The mathematical procedure is accompanied with physical explanations.
    Keywords: electric field, Maxwell's potential coefficients, equivalent ladder network

  5. Type of paper: Paper in journal

    Title: Transformer Tertiray and How To Handle It

    Authors:
    Kelemen, Tomislav (20682)
    Journal: ENERGIJA
    Number: 2
    ISSN: 0013-7448
    Volume: 43
    Year: 1994
    Pages: from 111 to 117
    Number of references: 7
    Language: hrvatski
    Summary: Tertiary - the low-voltage winding in a three-phase transformer with Yy-connected high-voltage and medium-voltage windings, delta-connected with terminals that make it capable of carrying loads, mostly dimensioned for one third of the transformer rated power - is frequently exposed to voltage and mechanical stresses which often result in transformer failures. Many of them could be avoided through appropriate protection of the tertiary, correct choice of the equipment that is connected to it and through its dimensioning that would be suited to possible voltage conditions in the network.
    Keywords: tertiary, stabilizing winding, failures, protection

  6. Type of paper: Paper in proceedings

    Title: Limitation of Overvoltages in Transformers by Means of Non-Linear Resistors

    Authors:
    Mikulecky, Antun (134543)
    Proceedings title: Zbornik radova XX. savjetovanja elektroenergetičara Jugoslavije JUNAKO CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1991
    Pages: from 97 to 106
    Meeting: XX. savjetovanje elektroenergetičara Jugoslavije JUNAKO CIGRE
    Held: from 04/22/91 to 04/26/91
    Summary: The tap and stabilizing windings of transformers are highlystressed by overvoltages in service and dielectric tests. Thesurpressing of overvoltages at these elements was doubtful tillthe application of oil-immersed gapless surge arresters. Tillnow, this solution has been applied in "Rade Končar" TransformerFactory on about 30 pcs. of large transformers. Besides the maincharacteristics of non-linear resistors ( metal-oxyde varistors), the problems related on their instalation and the principlesof their solutions, as well as the results of the electric testsof such transformers are present in the paper.
    Keywords: power transformer, overvoltage, surge arrester, impulse test

  7. Type of paper: Paper in proceedings

    Title: Steep Front Wave Propagation in Transformer Winding

    Authors:
    Kelemen, Tomislav (20682)
    Brkić, Luka (139293)
    Gardijan, Rajko (134475)
    Gojčeta, Zoran (129075)
    Mikulecky, Antun (134543)
    Editors
    Srb, Neven
    Proceedings title: Zbornik radova 3. međunarodnog simpozija o novim tehnologijama
    Language: hrvatski
    Place: Zagreb
    Year: 1991
    ISBN/ISSN: 86-81997-02-5
    Pages: from 161 to 164
    Meeting: 3. međunarodni simpozij o novim tehnologijama
    Held: from 10/15/91 to 10/17/91
    Summary: Steep front wave propagation in helical tertiary windings of verylarge transformers has been investigated as a part of aninvestigation of causes of tertiary winding failures. A view ofmeasured phenomena that explains the influence ofinterconnections of mutual inductances in winding on steep frontwave propagation is presented in the paper.
    Keywords: steep front wave, wave propagation, helical winding

  8. Type of paper: Paper in proceedings

    Title: Tertiary - Its Function, Failures and Protection

    Authors:
    Kelemen, Tomislav (20682)
    Editors
    Srb, Neven
    Proceedings title: Zbornik radova 4. međunarodnog simpozija o novim tehnologijama
    Language: hrvatski
    Place: Zagreb
    Year: 1993
    ISBN/ISSN: 86-81997
    Pages: from 8 to 13
    Meeting: 3. međunarodni simpozij o novim tehnologijama
    Held: from 10/25/93 to 10/27/93
    Summary: Tertiary - the low-voltage winding in a three-phase transformerwith Yy-connected high-voltage and medium-voltage windings,delta-connected with terminals that make it capable of carryingloads, mostly dimensioned for one third of transformer ratedpower - is frequently exposed to voltage and mechanical stressesoften resulting in transformer failures. Many of them could beavoided through appropriate protection of the tertiary; correctchoice of the equipment that is connected to it and through itsdimensioning that could be suited to possible voltage conditionsin the system.
    Keywords: tertiary, stabilizing winding, failures, protection

  9. Type of paper: Paper in proceedings

    Title: The Age of Transformers in the Power Supply System of Croatia

    Authors:
    Mikulecky, Antun (134543)
    Čabrajac, Sonja (7516)
    Gongola, Želimir
    Kelemen, Tomislav (20682)
    Mičuga, Josip
    Modrič, Željko
    Šutila, Stjepan
    Tadin, Frane
    Proceedings title: Zbornik radova 1. savjetovanja Hrvatskog komiteta CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1993
    Pages: from 167 to 176
    Meeting: 1. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 10/10/93 to 10/13/93
    Summary: The reliability of service of comparative old transformers can beensured by measures for prolonging their life or by lifeextension. On the basis of poll, the age of power transformers,highest system voltage from 123 kV to 420 kV, has been analysed.The result can be helpful in realising the priorities indetermination of the degree of transformer aging and their lifeextension. Because of rather numerous old transformers, the lifetheir proposal of the sequence of life extension acitivities.
    Keywords: power transformer, age, life extension

  10. Type of paper: Paper in proceedings

    Title: Life Extension of The Power Transformers

    Authors:
    Čabrajac, Sonja (7516)
    Mikulecky, Antun (134543)
    Proceedings title: Zbornik radova prvog savjetovanja Hrvatskog komiteta CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1993
    Pages: from 177 to 186
    Meeting: 1. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 10/10/93 to 10/13/93
    Summary: The portion of comparatively old components in electric powersystems is rather high. The more developed the system, the largertheir portion. Recently, great attention has been given to theanalysis of the aging of old components and to investigations ofpossibilities to extend their life. Thus, it is tried to reducethe costs of replacement of old components with new ones and toincrease the reliability of service of the old components. Theobjective of the paper is to present the results of the foreignand of our investigation on power transformers. The mechanisms oftransformer aging and the methods of life extension aredescribed. Some fundamental procedures and criteria for conditiondiagnosis of transformers as the basis for timely decision torenewal are proposed.
    Keywords: power transformer, aging, life extension

  11. Type of paper: Paper in proceedings

    Title: Testing of Distribution Transformers with Lineary Rising Overvoltage Chopped on the Front

    Authors:
    Gardijan, Rajko (134475)
    Proceedings title: Zbornik radova 1. savjetovanja Hrvatskog komiteta CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1993
    Pages: from 211 to 220
    Meeting: 1. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 10/10/93 to 10/13/93
    Summary: Failures of distribution transformers caused by flashovers on theprotective rod-gap have induced some clients to request newrequirements for their testing. In the paper, a method isdescribed for determination and measuring of steep-front orlineary rising front chopped shored impulses, and their nature isexplanied. A method for testing distribution transformers andverification of test results are described, too.
    Keywords: distribution transformers, steep-front short-duration surges, impulse voltage, test, wave steepness, protection

  12. Type of paper: Paper in proceedings

    Title: Limitation of Internal Overvoltages on Power Transformer Tertiary

    Authors:
    Mikulecky, Antun (134543)
    Editors
    Srb, Neven
    Proceedings title: Zbornik radova 4. međunarodnog simpozija o novim tehnologijama
    Language: hrvatski
    Place: Zagreb
    Year: 1993
    ISBN/ISSN: 86-81997
    Pages: from 4 to 7
    Meeting: 4. međunarodni simpozij o novim tehnologijama
    Held: from 10/25/93 to 10/27/93
    Summary: It is not possible to efficiently protect power transformersagainst internal or voltages using lightening arresters connectedto transformer terminals. The paper describes the limitation ofinternal overvoltages on power transformer tertiary windings bymeans of lightening arresters built-in the transformer.
    Keywords: power transformer, tertiary winding, overvoltage, overvoltage protection

  13. Type of paper: Paper in proceedings

    Title: The Commom Winding of Autotransformer and the Use of Tertiary

    Authors:
    Kelemen, Tomislav (20682)
    Proceedings title: Zbornik II. savjetovanja Hrvatskog komiteta CIGRE - Sekcija I: OPREMA
    Language: hrvatski
    Place: Zagreb
    Year: 1995
    ISBN/ISSN: 953-6408-01-5
    Pages: from 95 to 104
    Meeting: 2. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 05/14/95 to 05/18/95
    Summary: The three-phase autotransformer with tertiary winding is often used in high-voltage networks of 400, 220 and 110 kV. The tertiary is loaded as occasion demands, somewhere even for compensation of reactive power. The measures of overload protection are based on information about currents on all autotransformer voltage levels. If the tertiary winding is used for compensation, the common winding can become overloaded although none of the controlled currents exceeds the rated value. The problem is solved by control of the common winding current.
    Keywords: autotransformer, tertiary, common winding, compensation, overload

  14. Type of paper: Paper in proceedings

    Title: If Autotransformer Tertiary Winding is Loaded, the Common Winding Should Be Protected against Overload

    Authors:
    Kelemen, Tomislav (20682)
    Filipović-Grčić, Božidar (88083)
    Proceedings title: Zbornik referatov RZ-94
    Language: engleski
    Place: Ljubljana, R Slovenija
    Year: 1994
    Pages: from 71 to 79
    Meeting: IX. mednarodni simpozij o relejni zaščiti in lokalni avtomatizaciji elektroenergetskih sistemov
    Held: from 10/06/94 to 10/07/94
    Summary: The three-phase autotransformer with tertiary winding is often used in high voltage networks of 400, 220 and 110 kV. The tertiary is loaded as occasion demands, somewhere even for compensation of reactive power. The measures of overload protection are based on information about currents on all autotransformer voltage levels. If the tertiary winding is used for compensation, the common winding can become overloaded although none of the controlled currents exceeds the rated value. The problem is solved by control of the common winding current.
    Keywords: autotransformer, tertiary, common winding, compensation, overload

  15. Type of paper: Paper in proceedings

    Title: Model for Investigation of Transformer Insulation Ageing

    Authors:
    Mikulecky, Antun (134543)
    Čabrajac, Sonja (7516)
    Godec, Zdenko
    Proceedings title: Zbornik II. savjetovanja Hrvatskog komiteta CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1995
    ISBN/ISSN: 953-6408-01-5
    Pages: from 121 to 127
    Meeting: 2. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 05/14/95 to 05/18/95
    Summary: The remaining life of transformer insulation can be detremined by special diagnostic methods. A model for investigation of oil-immersed transformer insulation ageing is described in this paper. This model enables choosing and inspection of insulation ageing relevant parameters as well as application of diagnostic methods for determination of insulation ageing. The objective of the investigation is to define the correlation between direct and indirect diagnostic methods for determination of transformer insulation ageing state and also more reliable assessment of transformer insulation remaining life.
    Keywords: power transformer, diagnostics, insulation, ageing, model

  16. Type of paper: Paper in proceedings

    Title: Results of Electric Paper Ageing Tests of Transformers in Service

    Authors:
    Čabrajac, Sonja (7516)
    Mikulecky, Antun (134543)
    Podobnik, Vladimir (84053)
    Musulin, Božena (199891)
    Proceedings title: Zbornik radova II. savjetovanja Hrvatskog komiteta CIGRE
    Language: hrvatski
    Place: Zagreb
    Year: 1995
    ISBN/ISSN: 953-6408-01-5
    Pages: from 113 to 119
    Meeting: 2. savjetovanje Hrvatskog komiteta CIGRE
    Held: from 05/14/95 to 05/18/95
    Summary: For a number of years the ageing of electric paper has been tested by means of measurements of the average viscosimetric degree of polymerization of transformer paper. The results of tests made so far provide insight into the ageing of transformers in the Croatian power system. The paper explains the significance of the determination of paper ageing from the standpoints of transformer reliability. It also gives systematised test results and some comparison with data found in the literature. Some recommendations are given for future activities.
    Keywords: power transformer, testing, ageing, paper polymerisation degree

  17. Type of paper: Summary in proceedings

    Title: Large Scale Systems Modelling - Application of Sparse Matrix Hybrid Factorisation

    Authors:
    Bodlović, Petar (4186)
    Editors
    Srb, Neven
    Proceedings title: Zbornik radova 3. međunarodnog simpozija o novim tehnologijama
    Language: hrvatski
    Place: Zagreb
    Year: 1991
    ISBN/ISSN: 86-81997-02-5
    Pages: from 12 to 12
    Meeting: 3. međunarodni simpozij o novim tehnologijama
    Held: from 10/15/91 to 10/17/91
    Summary: Investigations of conditionality of the system of equations ofnetwork static state have shown that large-scale matrices areusually ill-conditioned. As solving of linear and linearisedlarge-scale system of equation finds many applications, the poor conditionality has given the incentive for investigations ofgeneralised solution on pseudosolutions of such systems.Pseudosolutions are common in the clasical problem of stateestimation. It is planned to investigate the applicability ofpseudosolution to the problems that include constraints in theform of inequalities, incomplete determination and optimisation. This investigation is based on the application of previouslydeveloped hybrid factorisation by efficient Gaussian eliminationand numerically stable transformations.
    Keywords: large-scale systems, pseudoinversion, sparse matrices

  18. Type of paper: Summary in proceedings

    Title: Transformer Exposed to System Transient Phenomena

    Authors:
    Kelemen, Tomislav (20682)
    Editors
    Srb, Neven
    Proceedings title: Zbornik radova 3. međunarodnog simpozija o novim tehnologijama
    Language: hrvatski
    Place: Zagreb
    Year: 1991
    ISBN/ISSN: 86-81997-02-5
    Pages: from 16 to 16
    Meeting: 3. međunarodni simpozij o novim tehnologijama
    Held: from 10/15/91 to 10/17/91
    Summary: At the end of seventies, there were several breakdowns oflow-voltage sides of large power transformers in Yugoslavia ( 300MVA, 400/115/31.5 kV, transformers manufactured by "Rade Koncar"Zagreb ). Something similar occured also in the beginning of the eighties on several similar transformers exported to Turkey,whose powers were half the above mention ones. The breakdownsoccured on tertiary windings, and were always preceded by faultsin other equipment ( circuit breakers, arresters, instrumenttransformers ). The investigations within this project have beenorganised so as to include : 1. Analysis of the stimuli and theircauses, 2. Investigations of transient phenomena during theinteraction between the transformer and the power system, 3.Investigation of some phenomena in the transformer from themoment of the stimulus till elimination of the disturbance orswitching off the transformer.
    Keywords: transformer, autotransformer, system transients, tertiary

  19. Type of paper: Summary in proceedings

    Title: Life Extension of Power Transformer Insulating System

    Authors:
    Mikulecky, Antun (134543)
    Godec, Zdenko
    Čabrajac, Sonja (7516)
    Proceedings title: Zbornik radova Stručne konzultacije "Obnova i izgradnja EES RH"
    Language: hrvatski
    Place: Zagreb
    Year: 1992
    Pages: from 0 to 0
    Meeting: Stručna konzultacija Obnova i izgradnja EES RH - HK CIGRE
    Held: from 05/26/92 to 05/27/92
    Summary: From the view of aging, large number of transformers in use bythe Croatian Power-Supply Company ( Hrvatska elektroprivreda )can be considered to have degraded reliability of operation. Thisdiscussion is aimed to direct the attention of transformer usersto the problem of transformer insulation aging, and to point tosome possible solutions.
    Keywords: power transformer, insulation, aging, life extension

  20. Type of paper: Summary in proceedings

    Title: The Refitting of Power Transformers for Operation in Wartime Conditions

    Authors:
    Mikulecky, Antun (134543)
    Proceedings title: Zbornik radova Stručne konzultacije Obnova i izgradnja EES RH
    Language: hrvatski
    Place: Zagreb
    Year: 1992
    Pages: from 0 to 0
    Meeting: Stručna konzultacija Obnova i izgradnja EES RH - HK CIGRE
    Held: from 05/26/92 to 05/27/92
    Summary: A description is given of the reffiting of power transformers inconditions when standard or prescribed procedures cannot beapplied.
    Keywords: Maintenance of transformers in wartime conditions, reffiting for operation in wartime conditions

  21. Type of paper: M.A.

    Title: Transformer Inrush Current
    Faculty: Elektrotehnički fakultet Zagreb
    Author: ADLER NEVENKA
    Date of defense: 01/28/92
    Language: hrvatski
    Number of pages: 102
    Summary: The paper deals with transformer inrush current phenomena whichbecome more important due to the use of new magnetic materialsand increase of transformer power. Most of known inrush currentinfluence factors were experimentaly investigated on one-phasetransformer model. All experimentaly obtained results werenumerically calculated. In the paper, the ninth order polinomialmodelling method for non-linear magnetic curve representation wasdeveloped. Characteristic interaction, immanent to theconnections of two or more transformers on the same busses andoccuring during inrush in one of them, was also tested andcalculated for the one-phase model. Taking into considerationnegative effects of inrush current upon differential protectionand the applicability of harmonic relays in the solution of thisproblems, inrush current was harmonically analysed by thestandard Fourier analysis and also by the Fourier integral.
    Keywords: transformer, inrush current, harmonic analysis, one-phase model, magnetic curve modelling


  22. Type of paper: M.A.

    Title: Optimization of Oil-immersed Distribution Transformers
    Faculty: Elektrotehnički fakultet Zagreb
    Author: GOJČETA ZORAN
    Date of defense: 12/22/92
    Language: hrvatski
    Number of pages: 84
    Summary: A mathematical method and a system of programs for numericalcalculations of oil-immersed distribution transformers aredescribed. The system of programmes has been arranged to fit theusers requirements. During preparation of the programmes therewere some additional changes of the mathematical model to improvethe convergence towards the optimum solution. At the optimumpoint, the variables must have descrete values, so that, besidesthe gradient method ( the method of steepest descent ) applied tocontinous domain optimisation, use was also made of thebranch-and-bound method for discretisations of variables. Theresult of optimisation is six-page print-out of a complete designsolution in accordance with existing documentation of the DesignOffice of "Končar - Distribution and Special Transformers" Ltd.The computation of personal computer is completely automatisedand it is also possible to run a series of computationsautomatically. A single computation on PC 80386/25 takes from 15to 45 minutes. The programmes is written in MS FORTRAN 5.1 andare stored in text-files and kept with both the author and theuser.
    Keywords: oil-immersed distribution transformer, mathematical model, optimisation, method of steepest descent, branch-and-bound method


  23. Type of paper: Mentorship

    Title: Transformer Inrush Current
    Faculty: Elektrotehnički fakultet Zagreb
    Mentor: KELEMEN TOMISLAV
    Date of defense: 01/28/92
    Number of pages: 102
    Author: Brkić dipl. ing. Luka
    Degree level: M.A.


  24. Type of paper: Mentorship

    Title: Optimisation of Oil-immersed Distribution Transformers
    Faculty: Elektrotehnički fakultet Zagreb
    Mentor: KELEMEN TOMISLAV
    Date of defense: 12/22/92
    Number of pages: 84
    Author: Gojčeta mr. Zoran
    Degree level: M.A.


  25. Type of paper: Survey/Study

    Title: Investigation of Failure of Capacitive Transformer VCU-420 in Tumbri Substation on March 19th 1993.

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Direkcija za upravljanje i prijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1993
    Number of pages: 50
    Language: hrvatski
    Summary: At the 400 kV substation in Tumbri near Zagreb there have beentwo explosions of capacitor voltage transformers in the period ofabout half a year. The neighbouring equipment was also damaged inthe explosion, yet there were no casualties. On the basis ofinspection of remains of exploded instrument transformers andchronological and oscilloperturbograph recording in the Tumbrisubstation ( Zagreb ) and Meline substation ( Rijeka ), data onthe 400 kV network and parameters of exploded transformers,mathematical simulation has been made of the events immediatelypreceding the explosions. The chronology of events before andafter explosion was reconstructed as well. Short-term andlong-term and preventive measures have been recomended in orderto reduce to minimum the probability of explosion. Reviewers ofthe Study : Božidar Grčić-Filipović, MSc. ( HEP Zagreb ) andMiroslav Mesić, BSc ( HEP Zagreb ). Public report on the Studytook place on December 10, 1993 at HEP Zagreb, Vukovarska 37 inthe presence of representatives of users and producers of HVequipment. The Study in general, the recommended preventivemeasures and the program of further investigations have beenaccepted.
    Keywords: instrument transformer, capacitor voltage transformer, fault, explosion

  26. Type of paper: Survey/Study

    Title: Investigation of Voltages on Capacitive Voltage Trasnformers at Switching on the 220-kV Transmission Line to Slavonija on July 31, 1993

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1994
    Number of pages: 16
    Language: hrvatski
    Summary: The phenomena recorded at switching on the transmission line to Slavonija in the Mraclin Substation on July 31, 1993 were explained by analysis of oscilloperturbograph recordings and by mathematical modelling. It was found that the circuit-breaker did not switch on in one phase. The transmission line was in war conditions, provisorily and without circuit-breaker connected to an autotransformer in the connection YNa0d5. At two-phase switching-on of the transmission line with autotransformer on its end there was ferroresonance of the system on 220 kV. The off line of phase S and the earthed autotransformer at the end of the line entered ferroresonant oscillations towards earth. The recorded duration of ferroresonance was about 1220 ms; the very beginning of ferroresonance was not recorded, and it was interrupted by switching off the transmission line in the Mraclin Substation. It is estimated that the overvoltage factor (in relation to the amplitude of the rated phase voltage) in phase S did not exceed 2. At visual analysis of recordings in August 1993 it was assessed that the ferroresonance occurred in the capacitor voltage transformer, that it was incited by switching on the transmission line and the capacitive voltage transformer together with the transmission line; it was also assessed that the ferroresonance was enabled by faulty filter for damping ferroresonance in capacitive voltage transformer. By inspection it was found that the filter was faulty, and it was replaced with a new, more up-to-date one. The investigation and the analysis of events recorded on July 31, 1993 showed that the capacitive voltage transformer in phase S was not in its own ferroresonance (as assumed) and that ferroresonance in the 220 kV network was registered through this transformer. It was found and explained that, at identical manipulation, ferroresonance is not possible if the off phase line is not connected with autotransformer. On the basis of the stated, the rule is to be introduced that in case of two-phase power supply (V connection) of a3-phase transformer the phase line not used should not be connected to the transformer. This applies equally to both high-voltage and medium voltage sides.
    Keywords: ferroresonance in high-voltage system, two-phase switching on
    Other: oznaka studije: IET 01-005

  27. Type of paper: Survey/Study

    Title: Testing and Adjustment of Protection of Autotransformer Tertiary for Loading with a 3x16.3 MVAr Capacitor Bank in the Mraclin Substation

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1994
    Number of pages: 22
    Language: hrvatski
    Summary: In the Mraclin Substation, three capacitor banks are connected to tertiary of autotransformer 150 MVA 220/115/10.5 kV in order to improve the power factor. Because of frequent failures, possible causes of overvoltage and measures for their elimination were analysed. Measures for prevention of ferroresonance, reduction of switching overvoltage, re-connection of lightening arrester sets and protection against short circuit on the tertiary are proposed. Switching manipulations on tertiary are considerably simplified.
    Keywords: tertiary, overvoltage, ferroresonance, compensation
    Other: oznaka studije: IET 01-007

  28. Type of paper: Survey/Study

    Title: Testing and Adjustment of Protection of Autotransformer Tertiaries for Home Supply in the Mraclin Substation in the Way that Will Enable Automatic Switching on the Side of the Tertiary

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1994
    Number of pages: 11
    Language: hrvatski
    Summary: In the Mraclin Substation, tertiaries of two autotransformers 150 MVA, 220/100/10.5 kV are used for station consumption. The existing solution is inappropriate for use, because each time the station transformer is off the 150 MVA autotransformer must also be switched off, and additionally it is necessary to go to the autotransformer to perform manual earthing of the connection of cx tertiary by means of a special earthing knife. After that the autotransformer can be switched on again. Equally inappropriate is the procedure for re-connection of station consumption to the tertiary. The objective of this task was to outline a proposal that will provide simple manipulations and a more reliable operation. The concept with reliable operation and simple manipulations that will at the same time enable automation of switching on the side of tertiary consists of reducing to the minimum the possible high switching overvoltages. It also includes measures for prevention and damping of ferroresonance. It is implemented by appropriate insulation of tertiary middle phase, by installation of resistors for damping of ferroresonance in auxiliary winding of the set consisting of three voltage transformers.
    Keywords: tertiary, protection of tertiary
    Other: oznaka studije: IET 01-008

  29. Type of paper: Survey/Study

    Title: Overload Protection of Common Winding of Autotransformers with Tertiary

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1994
    Number of pages: 17
    Language: hrvatski
    Summary: In three-phase autotransformers with loaded tertiary, the common winding of the autotransformer can be overloaded even if none of autotransformer rated currents is exceeded. The current of the common winding can be controlled by means of an intermediate current transformer and an overcurrent relay connected between secondaries of current transformers on HV and LV sides of the autotransformer. When the common winding is overloaded, instead of switching off the autotransformer, it is enough to switch of the tertiary load or a part of it. The problem of the overload of autotransformer common winding due to simultaneous loads of the secondary and tertiary grows as the transformation ratio U1a/Us2 lowers.
    Keywords: autotransformer, common winding, protection, overload
    Other: oznaka studije: IET 01-009

  30. Type of paper: Survey/Study

    Title: Failures in the Compensation Facility of the Substation Mraclin on September 3 and December 11, 1994 - Analysis of Causes and Proposed Measures

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1995
    Language: hrvatski
    Summary: Frequent failures of 10 kV compensation facility connected on the tertiary of 150 MVA autotransformer in the Mraclin Substation indicate that the existing circuit breaker is not capable of switching off failures such as those that occurred on 03.09. and 11.12. 1994. An apparently harmless failure (bridging of a capacitor through a bird) ends as a rule with a three-pole short circuit on the tertiary, destruction of circuit-breakers and damages of doors and windows in the building in which the switching installation is installed. It has been proven that the existing circuit-breaker type is not suitable for switching capacitor banks. Therefore, until new circuit breakers are bought, the protection against faults should be transferred to circuit breakers on the HV and LV sides of the transformer. In the meantime, it is necessary to implement measures of protection against bridging, build in resistors for limitation of discharge current under each capacitor bank, choose an up-to-date vacuum circuit-breaker which is capable of interrupting tipple rated capacitive current of the capacitor bank, as well as to implement the measures against short circuit on busbars which is caused by small animals (martens, cats, skunks etc.)
    Keywords: tertiary, compensation, failures, protective measures
    Other: oznaka studije: IET 01-010

  31. Type of paper: Survey/Study

    Title: Surge Overvoltage at Switching Off a Power Transformer Loaded with Induction Motor at the Praxair Station (Olen, Belgium)

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Končar - Distributivni i specijalni transformatori d.d.
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1995
    Number of pages: 22
    Language: hrvatski
    Summary: A 3 MVA 23/3 kV transformer loaded with an induction motor of 932 kW in no-load operation was heavily damaged during switching. Its manufacturer, the Zagreb factory Končar - Distributivni i specijalni transformatori d.d., was suspected as regards its quality. Investigations and mathematical modelling have shown that the transformer was not properly protected, because in the configuration such as that in Praxair, Belgium, high switching overvoltage is to be expected at switching off the transformer loaded with induction motor in no-load operation. The designer of the power station has not provided any overvoltage protection, and at the first manipulations some beginner's errors were made (switching on and off of the transformer loaded with a motor was performed in one second). Also the circuit breaker manufactured by ABB failed. The failure was observed only when the damaged voltage transformer was connected to the mains again. On this occasion, deformations of windings occurred that are characteristic of switching on previously damaged windings. The purchaser was made familiar with results of investigations, causes of the failure and possible measures for reduction of switching overvoltage. The purchaser, the Belgian company Depauw, has accepted and implemented the proposed measures of protection, and after that the power station was put into operation without any difficulties.
    Keywords: transformer, power cuts, switching overvoltage, overvoltage protection
    Other: oznaka studije: IET 01-023

  32. Type of paper: Survey/Study

    Title: Switching Overvoltage on Transformer HV Side at Switching Off a Transformer in Block Connection with Power Unit in the Station Kaersby (Vatten, Stockholm)

    Authors:
    Kelemen, Tomislav (20682)
    Ordering party: Končar - Distributivni i specijalni transformatori d.d.
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1995
    Number of pages: 36
    Language: hrvatski
    Summary: When the power station Kaersby near Stockholm was put into operation at the end of 1994, there were several failures of dry-type power transformers 2 MVA, 22+/-2x2.5%/0.4 kV. These generator transformers were fed from 2 MVA generators driven by diesel motors. Three of seven transformers were damaged before the station was put into operation. The Swedish contractor that managed the project claimed that the transformers were low quality. The investigations have shown that there was an error in the design of the station, because no overvoltage protection was provided. The modelling of overvoltage occurring at switching off the transformer in block connection with generator, vacuum circuit-breaker on the HV side, has shown that high switching overvoltage is to be expected on the HV side, right there where breakdowns among winding coils were found. To prove that the transformers are not good enough, the purchaser has sent the transformers to be tested at the HV Test Laboratory of ABB, but the test results were positive. When manipulations were performed again, one more transformer was damaged. In a study made for the needs of the company Končar - Distributivni i specijalni transformatori d.d., the observations made at inspection of damaged transformers have been explained, modelling results presented, and measures for reduction of switching overvoltages at switching conditions such as those at the Kaersby Power Station proposed.
    Keywords: transformer, power cuts, switching overvoltage, overvoltage protection
    Other: oznaka studije: IET 01-022

  33. Type of paper: Survey/Study

    Title: Investigation of Causes of Frequent Failures of Power Transfomers in the 110-kV Network within the Power Trasmission Area of Elektroprijenos - Opatija

    Authors:
    Kelemen, Tomislav (20682)
    Marušić, Ante (107554)
    Maljković, Zlatko (27746)
    Ordering party: Hrvatska elektroprivreda - Elektroprijenos
    Institution depot: Fakultet elektrotehnike i računarstva
    Year: 1995
    Number of pages: 52
    Language: hrvatski
    Summary: In a single month there were four heavy failures of 110+/-15%/36.75/10.5 kV transformers in substations that belong to the area of Elektroprijenos - Opatija. The investigations have shown that all the failures were results of radial forces that appear at short circuit. It has also been found that the heaviest failures take most time, often almost four seconds (2 seconds is the time allowed in the applicable IEC standard). After a complex analysis, measures for improvement of protection against short circuit, ferroresonance and failures on earthing resistors have been proposed. Procedures and requirements that have to be set when contracting repairs of damaged transformers and when ordering new ones are also specified.
    Keywords: transformer, failures, protection, forces
    Other: oznaka studije: ZES 485

  34. Type of paper: Survey/Study

    Title: Proposal of Recommendations for Regular Maintenance of Power Transformers above 5 MVA

    Authors:
    Mikulecky, Antun (134543)
    Godec, Zdenko
    Čabrajac, Sonja (7516)
    Ordering party: Hrvatska elektroprivreda - Direkcija za proizvodnju
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1993
    Number of pages: 57
    Language: hrvatski
    Summary: Thee Recommendation is the synthesis of many years of investigations of transformers, materials and events that happen in service. It contains a detailed description of power transformer diagnostics, maintenance, procedures in case of emergency and instructions for certain manipulations. So far it is the only integral survey of power transformer maintenance in Croatian. Plans for maintenance of power transformers are proposed, and all the necessary explanations are given, so that, besides standardisation of maintenance procedures, the Recommendation is a solid basis for training of personnel concerned with power transformer maintenance.
    Keywords: power transformer maintenance, diagnostics

  35. Type of paper: Survey/Study

    Title: General Design of Recovery of Synchronous Generators, Excitation System, Block Transformers and HV Cables at the Zakučac Hydroelectric Power Plant

    Authors:
    Čabrajac, Sonja (7516)
    Godec, Zdenko
    Knez, Nikola (188986)
    Mikulecky, Antun (134543)
    Podobnik, Vladimir (84053)
    Ordering party: Hrvatska elektroprivreda - PP HE Split, Pogon HE Zakučac
    Institution depot: Končar - Institut za elektrotehniku d.d.
    Year: 1995
    Number of pages: 28
    Language: hrvatski
    Summary: On the basis of electric tests of transformers and physical and chemical tests of samples of paper and oil from block transformers their condition is analysed and recommendations for extension of their life are given. The possibilities to increase their powers from 40 to 55 MVA and to use the existing 40 MVA transformers as stand-bys for the 50 MVA transformers are analysed. Technical specifications for the necessary new transformers in the Zakučac Power Plant are given.
    Keywords: ageing of power transformers, extenstion of life

  36. Type of paper: Invited lecture

    Title: Transformer Tertiary and How to Handle It
    Institution: Elektroprivreda Jordana
    Year: 1994