Title: Impact of network disturbances on turbogenerator dynamic strains

Authors:
Maljković, Zlatko (27746)
Kuterovac, Ljiljana (190751)
Novak, Davor
Glavan, Boris
Number: nik
ISSN: 961-6062-00-X
Volume: Zbor
Year: 1993
Pages: from 327 to 330
Number of references: 116
Language: engleski
Summary: The torsional oscillation computation for one combined networkdisturbance is shown for five different turbogenerator sets. Themodes of torsional modal vibrations, the electrical air-gaptorque responses and the shaft torques at coupling zones for thedisturbance mentioned are presented for the nuclear power plant(NPP) Krško. Performed computations show that the torsionalstrains should be computed separately because each turboset hasits own vibration mode.
Keywords: turbogenerator torsional strains, network disturbances

Title: The Analyses of Retardation Consequences on Turboset with Field Current

Authors:
Maljković, Zlatko (27746)
Sirotić, Zvonimir (43325)
Ban, Drago (1914)
Number: nik
ISSN: 953-6408-01-5
Volume: Zbor
Year: 1995
Pages: from 15 to 24
Number of references: 113
Language: hrvatski
Summary: The consequences of 376 MVA turbine-generator set retardation are analyzed. Turboset was disconnected from the network because of electrical system disturbance but owing to field current switch failure, excitation wasn't switched off. Using computer's program, rotor and stator winding heating are computed and influence of overheating on insulation is evaluated. The time of retardation and field current value limiting are the most important factors in this case. Rotor temperature was not higher than 159C assuming the duration of retardation with excitation was 10 min. Stator heating was within the limits taking into account the changing of stator losses.
Keywords: turbine-generator, losses, excitation

Title: Quality Assurance of Rotating Machines

Authors:
Kuterovac, Vladimir (78486)
Number: nik
ISSN: 953-6408-01-5
Volume: Zbor
Year: 1995
Pages: from 37 to 45
Number of references: 113
Language: hrvatski
Summary: Regarding to description of the CIGRE Study Committees activities, at the end of the year 1993 in Paris a new entry of "quality assurance" appeared as a field of activity in STK 11 - Rotacijski strojevi. The article discusses the possible scopes and ways of activities on the field of contemporary quality assurance conception and other actions in the SC 11, as well as the work organization in a small National Committee in the frame of CIGRE.
Keywords: quality assurance, rotating machines, ISO 9000 family, Croatia Committee CIGRE

Title: Necessity of Overspeed Test of the Electrical Rotating Machines

Authors:
Jarić, Vladimir (105383)
Kuterovac, Vladimir (78486)
Number: nik
ISSN: 953-6408-01-5
Volume: Zbor
Year: 1995
Pages: from 47 to 54
Number of references: 113
Language: hrvatski
Summary: Overspeed test is procedure which confirms the rotor monolithism and the function of other machine parts which take part actively. The test is performed with the highest possible expected speed which machine can experience during operation. Specifications of the overspeed tests are standarized by international standards. Latest edition of IEC 34-1 1994 standard is repeating the conclusion of former editions that overspeed test is normally considered as not necessary, but can be performed when agreed upon and specified so between manufacturer and customer. Therefore, the request should be pointed out regarding design of machines withstanding the speed standarized by this standard. This report considers elements influencing the decision on performing the overspeed test with their comprehensiveness.
Keywords: electrical rotating machines, overspeed test, runaway speed, overspeed, risk, reliability of structure

Title: Improvement of Design Process of Synchronous Generator

Authors:
Pužar, Milica (39413)
Mandić, Ivan (27930)
Tomljenović, Vesna
Number: nik
ISSN: 953-6408-01-5
Volume: Zbor
Year: 1995
Pages: from 65 to 71
Number of references: 113
Language: hrvatski
Summary: A design of a synchronous generator consists of a series of actions by which the generator is dimensioned, its parameters are computed and design documentation produced. For a large generator, it is almost always necessary to make new design according to customer requests. These requests are becoming more and more detailed and stringent, and terms for the design and tendering documentation production are shorter. In many cases the machine is designed only to make commercial offer, and the machine is never built. Regardless to this, high quality technical documentation is expected. If the ofer is accepted, a little can be changed afterwards. It is therefore important to make the best possible design at this stage. In this process the use of computers has become necessary, and the best solution represent incorporation of different design processes into a unified information system. Such system enables simple data input, computation and presentation of different parameters and also survey and use of data and solutions of earlier designs. The design and documentation production process is accelerated. The designer communicates with the system interactively, by means of menus and data editors. The requests upon the designer regarding the knowledge about software system configuration are minimal.