SVIBOR - Papers quoted in CC - project code: 2-15-121

MINISTRY OF SCIENCE AND TECHNOLOGY

Strossmayerov trg 4, HR - 10000 ZAGREB
tel.: +385 1 459 44 44, fax: +385 1 459 44 69
E-mail: ured@znanost.hr

SVIBOR

SVIBOR - Collecting Data on Projects in Croatia


Papers quoted in Current Contents on project 2-15-121


Quoted papers: 3
Other papers: 19
Total: 22


Title: MISCIBILITY OF POLY(VINYL CHLORIDE) WITH TERPOLY(alfa-METHYLSTYRENE-ACRYLONITRILE-METHYL METHAKRILATE)

Authors:
Kovačić, Tonka (22752)
Klarić, Ivka (21115)
Barić, Branka
Journal: POLIMERI
ISSN: -
Volume: 231
Year: 1994
Pages: from 215 to 223
Number of references: 16
Language: engleski
Summary: The miscibility of poly(vinyl chloride)/terpoly(alfa-methylstyrene-acrylonitrile-methylmethacrylate) (PVC/MS-AN-MMA) blend was investigated by differential scanning calorimetry. The parameters of thermal transitions and phase behaviour of the blend were determined. The miscibility of the blend with 0-40 and with more than 80 mass% of MS-AN-MMA was found. The depedence of glass transition temperature on the composition was well described by the Couchman, Gordon-Taylor and Fox equationa.
Keywords: PVC/MS-AN-MMA blends, differential scanning calorimetry, miscibility, kinetic equations

Title: KINETICS OF ISOTHERMAL THERMOGRAVIMETRICAL DEGRADATION OF PVC/ABS BLENDS

Authors:
Kovačić, Tonka (22752)
Klarić, Ivka (21115)
Roje, Urban (41413)
Kovačić, Tonka (22752)
Journal: Journal of Thermal Analysis
ISSN: 0022-5215
Number of references: 8
Language: engleski
Summary: The PVC/ABS blends were degradated by means of isothermal thermogravimetry at temperatures of 210-240 C in nitrogen. Applying the stationary point method apperent activation energy, preexponential factor and compensation parameter were calculated. Increasing the fraction of ABS in the blend up to 50% the kinetics of the process is changed.
Keywords: PVC/ABS blends, thermal degradation, thermogravimetric curves, kinetic parameters, stationary point method

Title: EFFECT OF HOMOGENEITY ON THE THERMAL DEGRADATION OF POLY(VINIYL CHLORIDE)/POLY(alfa-METHYLSTYRENE-ACRYLONITRILE-METHYLMETACRYLATE) BLENDS

Authors:
Kovačić, Tonka (22752)
Barić, Branka (188492)
Klarić, Ivka (21115)
Journal: Polymer Degradation and Stability
ISSN: 0141-3910
Number of references: 8
Language: engleski
Summary: The thermal degradation of homogenous and heterogenous PVC/MS-AN-MMA blends were investigated by means of dynamic thermogravimetry. The effect of degradation products of one polymer on the degradation process in the other polymer in the blend was stabilished. This effect is due to the fact that the phase diagram of PVC/MS-AN-MMA blend shows an upper critical solution temperatures. This means that all of the blend system are miscible at tempertures above the critical solution temperature.
Keywords: PVC/MS-AN-MMA blends, effect of homogeneity, thermal degradation, phase diagram


MZT Croatian language SVIBOR Alphabetic list Sorted on project code Sorted on institutions Search help
Ministry of
Science and
Technology
Croatian
language
Svibor
homepage
Alphabetic
list
Sorted on
project code
Sorted on
institutions
Search Help

Information: svibor@znanost.hr