SVIBOR - Papers quoted in CC - project code: 1-07-025
MINISTRY OF SCIENCE AND TECHNOLOGY
Strossmayerov trg 4, HR - 10000 ZAGREB
tel.: +385 1 459 44 44, fax: +385 1 459 44 69
E-mail: ured@znanost.hr
SVIBOR - Collecting Data on Projects in Croatia
Papers quoted in Current Contents on project 1-07-025
Quoted papers: 12
Other papers: 4
Total: 16
Title: Potentiometric determination of mercury(II) and thiourea
in strong acid solution using an ion-selective electrode with AgI-based
membrane hydrophobised by PTFE
- Authors:
- Radiĉ, Njegomir (39595)
- Komljenoviĉ, Josipa (119831)
Journal: Fresenius' Journal of Analitical Chemistry
ISSN: 0937-0633
Volume: 341
Year: 1991
Pages: from 592 to 596
Number of references: 18
Language: engleski
Summary: The potentiometric determination of mercury(II) and
thiourea(TU) in strong acid solution (pH 0 - 1) by using an
"all-solid-state" ion-selective electrode with (silver-sulfide 25%, AgI 25%
and PTFE 50% m/m) - membrane is described. Thelinear response, 43 mV/pHg
and 80 mV/pTU, has been obtained in the concentration range from 10 to
under 0.01 mmol/L. By direct potentiometry at pH 0 mercury(II) can be
determined in the presence of up to 1 mmol/L of iron(III). The change in
potential in the tested concentration range of thiourea indicates the
formation of Ag/TU = 0.7 at the exposed surface of the membrane. This
stoichiometry is in good agreement with that calculated fromthe average
Ag/TU ratio in the potentiometric titration. Theinvestigated electrode can
be used as a good sensor for mercury(II) and thiourea in strong acid media
and a wide variety of practical analytical systems.
Keywords: Mercury(II), thiourea, strong acid solution, potentiometric determination, iodide ion-selective electrode
Title: Potentiometric determination of thiourea by using
ion-selective electrode with AgI-based membrane hydrophobised with PTFE
- Authors:
- Komljenoviĉ, Josipa (119831)
- Radiĉ, Njegomir (39595)
Journal: Acta Pharm. Jugosl.
ISSN: 1330-0075
Volume: 41
Year: 1991
Pages: from 41 to 46
Number of references: 8
Language: engleski
Summary: Potentiometric determination of thiourea (TU) in strongly
acid solution (pH=1) by using "all-solid-state" ion-selective electrode
with (silver-sulfide 25%, AgI 25% and PTFE 50% m/m) -membrane is described.
The utilized sensing electrode has been prepared in the laboratory.
The equilibrium potentials observed during serial dilution or standard
addition, under constant pH and ionic strength, are plotted against log
c(TU). A linear response with a slope 80 mV/pTU has been obtained in the
concentration range from 10 to 0.01 mmol/L. The change in the potential, in
tested concentration range of thiourea, indicates Ag/TU=0.7 formation at
the exposed surface of membrane. The maximum response time of the
potentialcell with electrode was 1 min. even at low concentrations of
thiourea. The electrode reached a steady-state potential (drift0.3 mV/min)
within the time of experiments. In all experiments the potential drifts
were parallel and relatively small.
Keywords: Thiourea, potentiometric method, iodide ion-selective electrode
Title: Potentiometric determination of an overall formation
constant using an ion-selective membrane electrode
- Authors:
- Radiĉ, Njegomir (39595)
- Komljenoviĉ, Josipa (119831)
Journal: Journal of Chemical Education
Number: 6
ISSN: 0021-9584
Volume: 70
Year: 1993
Pages: from 509 to 511
Number of references: 6
Language: engleski
Summary: The development and application of ion-selective membrane
electrodes continues to be a rapidly growing area of analytical chemistry.
However in the standard analytical chemistry text book little attention is
given to this subject and there is a gap between the available teaching
sources and the research literature. This experiment introduces the student
to a potentiometric study of aluminium-fluoride complex formation in water
/ organic solvent mixtures, using a fluoride ion-selective electrode with
an La(III)-fluoride membrane. The electrode is used for determination of
free fluoride ions in solution. Based on the colected values of the
potentiometric titration experiment, the overall formation constant for
aluminium-fluoride complex in water/acetonitrile mixtures is determined.
Keywords: Aluminium-fluoride complex, overall formation constant, water + acetonitrile mixtures, fluoride ion-selective electrode
Title: Desing of a fluoride-selective electrode with internal
contact based on a Cu(II) ion-selective electrode
- Authors:
- Radiĉ, Njegomir (39595)
- Braliĉ, Marija (119816)
Journal: Microchemical Journal
ISSN: 0026-265
Volume: 48
Year: 1993
Pages: from 377 to 382
Number of references: 6
Language: engleski
Summary: The design of an electrode body that provides internal
contact with a La(III)-fluoride membrane based on a Cu(II) ion-selective
electrode is described. The assembled fluoride electrode was examined in
terms of potential-concentration curve sand potential-time response. The
behavior of the fluoride ion-selective electrode with the investigated
internal contact was in good agreement with the commercial fluoride
electrode.
Keywords: La(III)-fluoride membrane, internal contact, Cu(II) ion-selective electrode, fluoride ion-selective electrode
Title: Potentiometric determination of N-acetylcysteine based on
its reduction action on Fe(III)
- Authors:
- Komljenoviĉ, Josipa (119831)
- Radiĉ, Njegomir (39595)
Journal: Acta Pharmaceutica
Number: 2
ISSN: 1330-0075
Volume: 43
Year: 1993
Pages: from 99 to 106
Number of references: 15
Language: engleski
Summary: A simple potentiometric method for the determination of
N-acetylcysteine (NAC) is based on its reduction action on Fe(III) in
acidic fluoride solution, pH 2. The method is described as an equilibrium
method and kinetic method. The recorded potential value of the cell with
fluoride ion-selective electrode or the calculated average rate are found
to be linear with NAC concentration in solution. Good linearity is achieved
in the range of NAC concentration from 0.2 mmol/L to 1.5 mmol/L. The
kinetic method is proposed as the procedure of choice for the determination
of NAC in pure substances or in pharmaceutical formulations, with relative
standard deviation from 0.51 to 2.17%.
Keywords: N-acetylcysteine, potentiometric method, fluoride ion-selective electrode
Title: Kinetic-potentiometric determination of Fe(III) using a
fluoride ion-selective electrode
- Authors:
- Radiĉ, Njegomir (39595)
- Komljenoviĉ, Josipa (119831)
Journal: Croatica Chemica Acta
Number: 4
ISSN: 0011-1643
Volume: 64
Year: 1991
Pages: from 679 to 687
Number of references: 9
Language: engleski
Summary: A kinetic-potentiometric method is described for the
determination of Fe(III), based on monitoring of the formation of
Fe(III)-monofluoride in acid solution, using a fluoride ion-selective
electrode. The influence of pH and fluoride concentration in cell solution
on the kinetics of iron - fluoride reaction was studied. The initial rate
of the complex formation reaction, or change in potential during fixed time
interval (lminute), was used to construct calibration graphs. There is
alinear relationship between the calculated initial rate or (E-E')-1 min.
and concentration of iron in the cell solution. Good linearity (r=0.9979)
was achieved in the range of iron concentration from 0.035 to 1.4 mmol/L.
Keywords: Iron(III), kinetic-potentiometric determination, fluoride ion-selective electrode
Title: Direct Potentiometric Measurements of Cysteine by Using
Iodide-Selective Electrode
- Authors:
- Braliĉ, Marija (119816)
- Radiĉ, Njegomir (39595)
Journal: Croatica Chemica Acta
ISSN: 0011-1643
Volume: 67
Year: 1994
Pages: from 543 to 551
Number of references: 20
Language: engleski
Summary: Potentiometric determination of cysteine (Cys) in aqueous
solution by using iodide-selective electrode with (Ag2S + AgI) membrane is
described. The analytical behaviour of this electrode is discussed in terms
of the potential vs. concentration curve, potential vs. pH curve, and
potential-time response. The equilibrium potentials observed during serial
dilution or standard addition, under constant pH and ionic strenght, are
plotted against log c(Cys). The linear response with a slope 58 mV
p(Cys)ĉ-1 has been obtained in the concentration range from 310-3 to
under 10-5 M. The change in potential in the tested concentration range of
Cys (also designated as RSH) indicates RSAg coating formation at the
exposed membrane surface. On the basis of potentiometric experiments, the
solubility product of RSAg precipitate has been determined. The calculated
mean value was pKsp(RSAg) = 18,66+-0,08.
Keywords: Cysteine, potentiometric measurement, iodide ion-selective electrode
Title: Solid-state electrode with a Cu(I)-based membrane
hydrophobised by PTFE for the measurement of copper(II) and iodide ions
- Authors:
- Radiĉ, Njegomir (39595)
- Papa, Miljenko
Journal: Fresenius' Journal of Analitical Chemistry
ISSN: 0937-0633
Volume: 351
Year: 1995
Pages: from 599 to 603
Number of references: 14
Language: engleski
Summary: The preparation of CuI + Ag2S and Cu2HgI4Ĉ + Ag2S membrane
hydrophobised by PTFE is described. The pressed membranes mounted in a
multi-purpouse "all-solid-state" electrode body have been examined as
electrochemical sensors for copper(II) and iodine ions. For the electrode
with (CuI + Ag2S + PTFE)-membrane experimental slopes of 29 mV(pCu)-1 and
62 mV(pI)-1 were obtained, in good agreement with the theoretical values.
For practical measurement in solutions where both copper(II) and iodine
ions can be present, the investigated electrode offers certain advantages
in comparasion with a comercial Cu-ISE.
Keywords: Copper, iodide, potentiometric measurement, Cu(I)-based membrane electrode
Title: Design and properties of flow-through electrode with
AgI-based membrane hydrophobised by PTFE; application to flow-injection
determination of thiourea
- Authors:
- Komljenoviĉ, Josipa (119831)
- Radiĉ, Njegomir (39595)
Journal: Sensors and Actuators B
ISSN: 0925-4005
Volume: 24
Year: 1995
Pages: from 312 to 316
Number of references: 8
Language: engleski
Summary: A multi-purpose solid-state iodide-selective electrode is
constructed as a compact tubular sensor; the sensing hole has 2,0 mm i.d.
and 1,2 mm length. The behaviour, suitability and incorporation of the
tubular electrode into the conduit of a flow-injection system are
described. Application of the tubular electrode is exemplified by the
determination of thiourea in 0,1 M HClO4 as supporting electrolyte by using
of a flow-injection system. A rectilinear calibration graph is obtained by
plotting the peak hight versus concentration of thiourea. The detection
limit is 0,02 mM under optimized flow conditions (1,2 mL/min; 0,2 mL
samples, 10-5 M silver ions in the carrier stream).
Keywords: Flow-injection analysis, membrane electrode, thiourea
Title: Electroanalytical Study of Aluminium Fluoride Complexation
in 2-Propanol-Water Mixtures
- Authors:
- Radiĉ, Njegomir (39595)
- Papa, Miljenko
Journal: Analytical Sciences
ISSN: 0910-6340
Volume: 11
Year: 1995
Pages: from 425 to 429
Number of references: 12
Language: engleski
Summary: Theoretical approaches to aluminium-ion by two
potentiometric methods (potentiometric titration and analyte subtraction
potentiometry) are discussed. The computed theoretical titration curves
show that the equivalence point is signaled by a sufficiently large change
in the potential only in media where aluminium forms a hexafluoride
complex; the overall formation constants á(AlF6-3)>=10+28. On the basic of
potentiometric titration and zhe known subtraction experiments in
2-propanol + water, buffered with acetate buffer (pH 5), the overall
conditional constants (á') were calculated. The calculated average
á'-values are 10+33, depending of the vol% of organic solvent, 50% and 67%.
In the mixtures having a vol% of organic solvent of 50% or 67%, both metods
can be applied for the determination of aluminium, via AlF6-3 complex
formation, in the concentration range from 10-4 to 10-3 M.
Keywords: Potentiometry, fluoride-electrode, aluminium, nonaqueous media
Title: Fluoride-Selective Electrode with Internal Redox Reference
Electrode
- Authors:
- Radiĉ, Njegomir (39595)
- Braliĉ, Marija (119816)
Journal: Microchemica Acta
ISSN: 0026-3672
Volume: 118
Year: 1995
Pages: from 221 to 227
Number of references: 11
Language: engleski
Summary: The potential response of a symmetrical configuration in
which the LaF3-membrane is placed between two solutions is discussed. The
electrode body provides contact with the inner surface of the fluoride
membrane, with solution containing Fe(CN)6-3 / Fe(CN)6-4 redox couple and
Pt wire as internal reference electrode. The electrode was examined in
terms of potential-concentration curves and potential-time response and
shown to behave similarly to the commercial Orion fluoride electrode. The
advantage of the proposed redox reference system is that the electrode has
minimal drift immediately after assembly.
3
1
Keywords: Fluoride ion-selective electrode, LaF3-membrane, internal redox contact
Title: "Programmable" Selective Inexpesive Potentiometric
Detector for Flow Injection Analysis. Potassium Determination with a Nafion
Membrane Modifed Electrode
- Authors:
- Akmal, N
- Lunsford, S.K
- Galal, A
- Karagozler, A.E
- Mark, H.B
- Radiĉ, Njegomir (39595)
Journal: Croatica Chemica Acta
ISSN: 0011-1643
Volume: 68
Year: 1995
Pages: from 403 to 407
Number of references: 17
Language: engleski
Summary: The study of nafion membrane (ISE membrane) for the
inexpensive potentiometric detection of potassium ion in a flow injection
system is reported. The nafion membrane doped with potassium ion showed
that excelent selectivity could be achieved for various cations, except
for Rb+, and some interference for Cs+. A linear potential response of from
10-2 to 10-6 M for the potassium ion was obtained with a detection limit of
about 510-6 M. This approach can be employed for constructing a
poetntiometric detector for virtually any cation (soluble at basic pH
values) by simply changing the electrode pretreatment (or doping solution).
Keywords: Potassium, potentiometric determination, flow-injection analysis, nafion-membrane
Information: svibor@znanost.hr